Support FAQ

In the highly competitive automotive glass industry, we have achieved the reputation as the industry leader by continuously advancing technology and providing consistent quality product to our customers. We look forward to the opportunity to provide this same level of service to your facility.

Where can I find a troubleshooting guide?

We have a troubleshooting flow chart available below as a PDF download:

What are the air and electrical requirements for a Q-box?

MODEL Antaya P/N POWER Requirement AIR Requirement
Series V-1 (110V) 90856 100-120 VAC, 10 Amps, 60 Hz Single Phase 70-125 PSI, 4-6 CFM
Series V-1 (230V) 90857 200-240 VAC, 5 Amps, 50 Hz Single Phase 70-125 PSI, 4-6 CFM
Series V-2 (110V) 90843 100-120 VAC, 20 Amps, 60 Hz Single Phase 70-125 PSI, 6.8-9.4 CFM
Series V-2 (230V) 90845 200-240 VAC, 10 Amps, 50 Hz Single Phase 70-125 PSI, 6.8-9.4 CFM
Series V-3 (230V) 90874 200-240 VAC, 15 Amps, 50/60 Hz Single Phase 70-125 PSI, 9-12 CFM
Series V-4 (230V) 90875 200-240 VAC, 20 Amps, 50 Hz Single Phase 70-125 PSI, 9-12 CFM

What solder alloy is best for my application?

SOLDER TYPE MEETS STANDARD
Type B604 LEAD-FREE compliant AK 2.1; SAE USCAR 40
Type B601 LEAD-FREE compliant AK 2.1; SAE USCAR 40
Type 65 LEAD-FREE compliant SAE USCAR 40
4-PART with LEAD N/A
3-PART with LEAD N/A

Call and speak with our technical support staff for more specific recommendations for your project.

How can I request a quote?

To request a quote on a new or existing part, visit our Part RFQ here.

For a quote on equipment, visit our Equipment RFQ here.